Copley XEC sets new levels of performance, connectivity, and flexibility. CANopen application protocol over EtherCAT (CoE) communication provides a widely used, cost-effective industrial bus. A wide range of absolute encoders are supported. High-resolution A/D converters ensure optimal current loop performance. Both isolated and high-speed non-isolated I/O are provided. For safety critical applications, redundant power stage enabled inputs can be employed.

  • Power Levels: 3, 6, & 7.5 Amps Cont.
  • Control modes: Cyclic Synchronous Position-Velocity-Torque (CSP, CSV, CST), Position(step & direction), Velocity(+/-10V) & Torque(+/-10V), Camming, Gearing
  • Command Interface: CANopen application protocol over EtherCAT (CoE), ASCII, discrete I/O, Stepper command, +/-10V Position/Velocity/Torque, PWM velocity & torque command
  • Communications: EtherCAT, RS-232
  • Feedback: Digital quad A/B encoder, Secondary encoder/emulated encoder out, Analog sin/cos encoder option, Absolute (EnDat 2.1 & 2.2, BiSS, SSI), Digital Halls
  • I/O - Digital: 11 inputs, 5 outputs
  • Dimensions: 191.4 x 115.6 x 54.1 mm, 7.54 x 4.55 x 2.13 in

Catalog & Specifications
Copley XEC Datasheet 

User Guides
Copley XEC Hardware User Guide
Copley XEC CME2 User Guide
Copley XEC ASCII Programmers Guide
Copley XEC CMO (Copley Motion Objects) Guide
Copley XEC Indexer User Guide

Drawings
Copley XEC Drawings (dxf, stp)

Software
CME 2 Software